Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. dent. j ; 26(6): 660-666, Nov.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-769547

ABSTRACT

The aim of this study was to evaluate the corrosion resistance of pure titanium grade 4 (cp-Ti-4), subjected to disinfection with 0.2% and 2% peracetic acid during different immersion periods using anodic potentiodynamic polarization test in acid and neutral artificial saliva. Cylindrical samples of cp-Ti-4 (5 mm x 5 mm) were used to fabricate 24 working electrodes, which were mechanically polished and divided into eight groups (n=3) for disinfection in 2% and 0.2% peracetic acid for 30 and 120 min. After disinfection, anodic polarization was performed in artificial saliva with pH 4.8 and 6.8 to assess the electrochemical behavior of the electrodes. A conventional electrochemical cell, constituting a reference electrode, a platinum counter electrode, and the working electrode (cp-Ti specimens) were used with a scanning rate of 1 mV/s. Three curves were obtained for each working electrode, and corrosion was characterized by using scanning electron microscopy (SEM) and energy dispersive x-ray spectrometry (EDS). Data of corrosion potential (Ecorr) and passive current (Ipass) obtained by the polarization curves were analyzed statistically by Student's t-test (a=0.05). The statistical analysis showed no significant differences (p>0.05) between artificial saliva types at different concentrations and periods of disinfection, as well as between control and experimental groups. No surface changes were observed in all groups evaluated. In conclusion, disinfection with 0.2% and 2% peracetic acid concentrations did not cause corrosion in samples manufactured with cp-Ti-4.


Resumo O objetivo deste estudo foi avaliar a resistência à corrosão de titânio puro grau 4 (cp-Ti-4) submetido à desinfecção com ácido peracético a 0,2% e 2% durante diferentes períodos de imersão por meio do teste de polarização potenciodinâmica anódica em saliva artificial ácida e neutra. Amostras cilíndricas de cp-Ti-4 (5 mm x 5 mm) foram usadas para confeccionar 24 eletrodos de trabalho, os quais foram polidos mecanicamente e divididos em oito grupos (n=3) para desinfecção com ácido peracético a 2% e 0,2% por 30 e 120 minutos. Após a desinfecção, foi realizado o teste de a polarização anódica em saliva artificial com pH 4,8 e 6,8 para avaliar o comportamento eletroquímico dos eletrodos. Uma célula electroquímica convencional, composta por eletrodo de referência, contra-eletrodo de platina, e eletrodo de trabalho (amostras de cp-Ti) foi usada com taxa de varredura de 1 mV/s. Foram obtidas três curvas para cada eletrodo de trabalho e a corrosão foi analisada por microscopia eletrônica de varredura (MEV) e espectrometria de energia dispersiva de raios-X (EEDX). Os dados de potencial de corrosão (Ecorr) e corrente passiva (Ipass) obtidos com as curvas de polarização foram analisados estatisticamente pelo teste t de Student (=0,05). A análise estatística não mostrou diferenças significantes (p>0,05) entre os tipos de saliva artificial nas diferentes concentrações e períodos de desinfecção, bem como entre os grupos controle e experimental. Não foram observadas alterações nas superfícies das amostras de todos os grupos avaliados. Conclui-se que a desinfecção com ácido peracético nas concentrações de 0,2% e 2% não provocou corrosão nas amostras confeccionadas com cp-Ti-4.


Subject(s)
Corrosion , Peracetic Acid/chemistry , Titanium/chemistry , Microscopy, Electron, Scanning , Spectrometry, X-Ray Emission
2.
Braz. dent. j ; 25(2): 136-140, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-719210

ABSTRACT

The aim of this study was to determine the tensile strength of crowns cemented on metallic substrate with four different types of luting agents. Twenty human maxillary molars with similar diameters were selected and prepared to receive metallic core castings (Cu-Al). After cementation and preparation the cores were measured and the area of crown's portion was calculated. The teeth were divided into four groups based on the luting agent used to cement the crowns: zinc phosphate cement; glass ionomer cement; resin cement Rely X; and resin cement Panavia F. The teeth with the crowns cemented were subjected to thermocycling and later to the tensile strength test using universal testing machine with a load cell of 200 kgf and a crosshead speed of 0.5 mm/min. The load required to dislodge the crowns was recorded and converted to MPa/mm2. Data were subjected to Kruskal-Wallis analysis with a significance level of 1%. Panavia F showed significantly higher retention in core casts (3.067 MPa/mm2), when compared with the other cements. Rely X showed a mean retention value of 1.877 MPa/mm2 and the zinc phosphate cement with 1.155 MPa/mm2. Glass ionomer cement (0.884 MPa/mm2) exhibited the lowest tensile strength value. Crowns cemented with Panavia F on cast metallic posts and cores presented higher tensile strength. The glass ionomer cement showed the lowest tensile strength among all the cements studied.


O objetivo deste estudo foi determinar a resistência à tração de coroas cimentadas em substrato metálico com quatro diferentes tipos de agentes cimentantes. Vinte molares humanos maxilares com diâmetros semelhantes foram selecionados e preparados para receberem núcleos metálicos fundidos (Cu-Al). Após cimentação e preparo, os núcleos foram mensurados e a área da porção coronária foi calculada. Os dentes foram divididos em quatro grupos baseados no agente cimentante utilizado para cimentar as coroas: cimento de fosfato de zinco; cimento de vidro ionômero; cimento resinoso Rely X; e cimento resinoso Panavia F. Os dentes com as coroas cimentadas foram submetidos a termociclagem e logo à prova de resistência à tração usando a máquina de ensaios universal com uma célula de carga de 200 kgf e uma velocidade de 0,5 mm/min. A carga necessária para deslocar as coroas foi registrada e convertida a MPa/mm2. Os dados foram submetidos ao análise de Kruskal-Wallis com um nível de significância de 1%. Panavia F mostrou uma retenção significativamente maior nos núcleos fundidos (3,067 MPa/mm2), quando comparados com os outros cimentos. Rely X mostrou um valor médio de retenção de 1,877 MPa/mm2 e o cimento de fosfato de zinco com 1,155 MPa/mm2. O cimento de vidro ionômero (0,884 MPa/mm2) exibiu o menor valor de resistência à tração. As coroas cimentadas com Panavia F nos pinos e núcleos metálicos fundidos apresentaram maior resistência à tração. O cimento de ionômero de vidro mostrou o menor valor de resistência à tração entre todos os cimentos estudados.


Subject(s)
Dental Cements , Metals , Tensile Strength , In Vitro Techniques
SELECTION OF CITATIONS
SEARCH DETAIL